Sprinkler Systems
Pipes/Plumbing
Electrical Lighting and Fixtures
HVAC Equipment and Fixtures
The patent-pending X-Press Anchors consist of a threaded fastener and expandable sleeve. The X-Press System features an easy-to-install anchor with expanding anchoring strips that collapse to prevent pullout after installation. The Sammy X-Press® It Installation Tool assures a perfect installation every time offering the added convenience of one-tool efficiency – just drill and drive in seconds! SECONDS!
The Sammy X-Press® System is designed to provide direct attachment of threaded rod in metal deck (22-16 gauge) and thin gauge purlin (18-16 gauge), while providing reduced installation costs in terms of time and materials. The X-Press Anchors eliminate the need for costly “armovers” in pipe hanging installations. Current methods offered for thin gauge purlin require use of a time-consuming retaining nut on the threaded portion of the fastener to prevent pullout and are not designed for use in metal deck. In many instances, access to the backside of the installed fastener is prohibited by panel liner or roofing insulation. Sammy X-Press® anchors deliver the performance installers require without the use of a retaining nut!
Structural attachment for installation of branch/end of line restraint using 3/8″ threaded rod. Used primarily in purlin, bar joist, or other steel structural members. These fastening systems provide a secure and economical attachment to the structure.
The SWXP 35 model provides upper structural attachment in a range of steel thicknesses, from 16 ga. through 1/8″. An expandable sleeve is included with each fastener, eliminating need for retaining nut.
FEATURES
BENEFITS
Restrained Pipe Size: Up to Schedule 40 pipe 2″ or less
Max Length of Restraint Material: See Maximum Horizontal Load Tables below.
Maximum Angle: 45° from horizontal
Material: Carbon Steel
Screw Description: 1/4″-20 x 1-1/8″ with expandable sleeve
Finish: Electro-Zinc
Testing: Tested to GR-63-CORE Standard for performance in structural steel in seismic restraint applications as outlined for use in NFPA 13 (2007), 9.3 at an independent test lab. The calculated force used for the testing was equal to that found in a Zone 4 and an 8.4 Richter scale seismic event.
Listing for 3/8″ Rod: UL 203 listed as pipe hanger File EX 5098 – SXP 35 (16 ga.) 0-90° from horizontal – 3-1/2″ Schedule 40 pipe UL 203A File EX 15565
Restrained Pipe Size: Up to Schedule 40 pipe 2″ or less
Max Length of Restraint Material: See Maximum Horizontal Load Tables below.
Maximum Angle: 45° from horizontal
Material: Carbon Steel
Screw Description: 1/4″-20 X 1-1/8″ with expandable sleeve
Finish: Electro-Zinc (cap & screw)
Testing: BX Report # R-1362
Listing: UL 203 as a pipe hanger – UL 203A pending
To view our catalog pages, click here; and for our seismic performance tables, click here. (will open a new tab)
Sprinkler Systems
Pipes/Plumbing
Electrical Lighting and Fixtures
HVAC Equipment and Fixtures
SAMMY X-PRESS IT® INSTALLATION TOOL |
|||
PART NUMBER | MODEL | DESCRIPTION | EACH QTY |
8194910 | UXPIT* | Universal X-Press It Tool | 1 |
8152910 | XPDB | 25/64" Drill Bit | 1 |
*Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64” Drill Bit.
SAMMYS X-Press Vertical Mount |
||||||||||||
ROD SIZE | PART NUMBER | MODEL | DESCRIPTION | ULTIMATE PULLOUT (LBS) | TEST LOAD (LBS) | UL MIN THICK | TEST LOAD (LBS) | FM MIN THICK | MAX THICK | BOX QTY | CASE QTY | APPLICATION |
1/4" | 8181922 | XP 200 | X-Press 200 | 1146 (22 ga) | 185 (Luminaire) 250 (Luminaire) | .027" .056” | - | - | .125” | 25 | 125 | Metal Deck |
3/8" | 8150922 | XP 20 | X-Press 20 | 1146 (22 ga) | 850 (2½" Pipe) 185 (Luminaire) 250 (Luminaire) 283 (Conduit & Cable) | .027" .027” .056” .029" | 940 (2" Pipe) 1475 (4” Pipe) | .029” .104” | .125” | 25 | 125 | Metal Deck |
3/8" | 8153922 | XP 35 | X-Press 35 | 1783 (16 ga) | 1500 (4" Pipe) 85 (Luminaire) 250 (Luminaire) 416 (Conduit & Cable) | .060” .029” .056” .059” | 940 (2" Pipe) 1475 (4” Pipe) | .029” .104” | .125” | 25 | 125 | Purlin |
3/8" | 8150922 | XP 20 | X-Press 20 | 1146 (22 ga) | 850 (2½ Pipe) | - | Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWC≤ 35 PCF (lbs/ ft³) | - | - | 25 | 125 | Metal Deck (Pre-Pour) Metal Deck (Post-Pour) |
SAMMYS X-Press Swivel Head® |
||||||||||||
ROD SIZE | PART NUMBER | MODEL | DESCRIPTION | ULTIMATE PULLOUT (LBS) | TEST LOAD (LBS) | UL MIN THICK | TEST LOAD (LBS) | FM MIN THICK | MAX THICK | BOX QTY | CASE QTY | APPLICATION |
3/8" | 8295922 | SXP 35 | Swivel X-Press 35 | 1675 (16 ga Vertical) 1558 (89° Off Vertical) | 1250 (3-1/2" Pipe) 250 vertical (Luminaire) 80 @ 90° (Luminaire) 500 vertical (Conduit & Cable) 333 @ 89° (Conduit & Cable) | .059” | 635 (2" Pipe) | .029" | .125” | 25 | 125 | Purlin |
SAMMYS X-Press Horizontal Mount |
||||||||||||
ROD SIZE | PART NUMBER | MODEL | DESCRIPTION | ULTIMATE PULLOUT (LBS) | TEST LOAD (LBS) | MIN THICK | MAX THICK | BOX QTY | CASE QTY | APPLICATION | ||
3/8" | 8293957 | SWXP 35 | Sidewinder X-Press 35 | 1798 (16 ga) | 1250 (3½" Pipe) 80 (Luminaire) 416 (Conduit & Cable) | .060” | .125” | 25 | 125 | Purlin |
SAMMYS X-Press Swivels – Seismic Restraint |
||||||||
ROD SIZE | PART NUMBER | MODEL | MIN THICKNESS | MAX THICKNESS | APPLICATION | BOX QTY | CASE QTY | INSTALLATION TOOL |
3/8" | 8295922 | SXP 35 | 16 ga | 1/8" | Purlin | 25 | 125 | The SWXP 35 must be installed with UXPIT Tool (Part No. 8194910); pre-drilling required. |
SAMMYS Sidewinders for Steel – Seismic Restraint |
||||||||
ROD SIZE | PART NUMBER | MODEL | MIN THICKNESS | MAX THICKNESS | APPLICATION | BOX QTY | CASE QTY | INSTALLATION TOOL |
3/8" | 8293957 | SWXP 35 | 16 ga. | 1/8" | Steel Purlin or Bar Joist | 25 | 125 | The SWXP 35 must be installed with UXPIT Tool (Part No. 8194910); pre-drilling required. |
The X-Press System has earned the 9R21 and 25ES UL Listing.